Home | About Journal  | Editorial Board  | Instruction | Subscription | Advertisement | Message Board  | Contact Us | 中文
MODERN TUNNELLING TECHNOLOGY 2023, Vol. 60 Issue (5) :111-119    DOI:
Current Issue | Next Issue | Archive | Adv Search << [an error occurred while processing this directive] | [an error occurred while processing this directive] >>
Study on Fire Smoke Spreading Characteristics in Asymmetric V-Slope Highway Tunnel
2. Center for Balance Architecture, Zhejiang University, Hangzhou 310007; 3. Zhejiang University Zhongyuan Institute,Zhengzhou 450000; 4. General Supervision Station of Construction Engineering Quality and Safety of Fuyang District, Hangzhou,Hangzhou 311400; 5. China Railway Siyuan Survey and Design Group Co., Ltd., Hangzhou 310000)
Download: PDF (4442KB)   HTML (1KB)   Export: BibTeX or EndNote (RIS)      Supporting Info
Abstract Underwater tunnels are often high at both ends and low in the middle, showing the "V" shape, with high fire risk. Therefore, mastering the characteristics of fire smoke spreading is the basis of fire emergency response,evacuation and rescue work. The Fire Dynamics Simulation software (FDS) is used to build the asymmetric V-slope tunnel fire model under the condition of natural ventilation, to study the spreading process of fire smoke under different combination of slopes, and to analyze the changes of smoke pressure and velocity at the tunnel portal on both sides of the tunnel. The results show that: after a fire occurs at the slope change point, the smoke spreading in the asymmetric V-slope tunnel presents the multi-phase spreading characteristics similar to that in the single-slope tunnel,but the smoke spreading velocity on the high slope side is slower than that in the single slope tunnel, while the smoke spreading velocity on the low slope side is faster, and the steady back-flow length of fire smoke is shorter; In the process of smoke spreading in the asymmetric V-slope tunnel, there exist three characteristic stages: flow field remodeling, forward dynamic cycle reconstruction, and maintaining stability; The maximum back-flow length and the steady back-flow length of the tunnel smoke on the low slope side and their corresponding moments are jointly affected by the tunnel slope gradients on both sides and the gradient difference, and there is a critical gradient difference of 4%. When the gradient difference is greater than 4%, the characteristics of fire smoke spreading will no longer be affected by the gradient difference.
Service
Email this article
Add to my bookshelf
Add to citation manager
Email Alert
RSS
Articles by authors
LI Xiang1
2 CHEN Xiaofeng1
2
3 BA Weijun4 WANG Xiaofei5 YU Junxiang2 ZHENG Jun1
2 WU Ke1
2
3
KeywordsTunnel fire   asymmetric V-slope   FDS   spread characteristics   dynamics mechanism   tunnel gradient     
Abstract: Underwater tunnels are often high at both ends and low in the middle, showing the "V" shape, with high fire risk. Therefore, mastering the characteristics of fire smoke spreading is the basis of fire emergency response,evacuation and rescue work. The Fire Dynamics Simulation software (FDS) is used to build the asymmetric V-slope tunnel fire model under the condition of natural ventilation, to study the spreading process of fire smoke under different combination of slopes, and to analyze the changes of smoke pressure and velocity at the tunnel portal on both sides of the tunnel. The results show that: after a fire occurs at the slope change point, the smoke spreading in the asymmetric V-slope tunnel presents the multi-phase spreading characteristics similar to that in the single-slope tunnel,but the smoke spreading velocity on the high slope side is slower than that in the single slope tunnel, while the smoke spreading velocity on the low slope side is faster, and the steady back-flow length of fire smoke is shorter; In the process of smoke spreading in the asymmetric V-slope tunnel, there exist three characteristic stages: flow field remodeling, forward dynamic cycle reconstruction, and maintaining stability; The maximum back-flow length and the steady back-flow length of the tunnel smoke on the low slope side and their corresponding moments are jointly affected by the tunnel slope gradients on both sides and the gradient difference, and there is a critical gradient difference of 4%. When the gradient difference is greater than 4%, the characteristics of fire smoke spreading will no longer be affected by the gradient difference.
KeywordsTunnel fire,   asymmetric V-slope,   FDS,   spread characteristics,   dynamics mechanism,   tunnel gradient     
Cite this article:   
LI Xiang1, 2 CHEN Xiaofeng1, 2 etc .Study on Fire Smoke Spreading Characteristics in Asymmetric V-Slope Highway Tunnel[J]  MODERN TUNNELLING TECHNOLOGY, 2023,V60(5): 111-119
URL:  
http://www.xdsdjs.com/EN/      或     http://www.xdsdjs.com/EN/Y2023/V60/I5/111
 
No references of article
[1] TAN Yinjun1,2 WANG Keli1,2 ZHANG Heng1,2 ZHANG Zhiqiang1,2.Influence of Natural Wind on Fire Smoke Propagation in 10 km Long Highway Tunnels[J]. MODERN TUNNELLING TECHNOLOGY, 2025,62(1): 103-113
[2] GUO Chao1,2 YAN Zhiguo1,2 LI Wei1,2 ZHOU Xifang3.A Full-scale Experimental Study on the Fire Characteristics of Dual-source Tunnel Fire[J]. MODERN TUNNELLING TECHNOLOGY, 2023,60(2): 247-259
[3] HAN Xingbo1,2 XIA Yongxu1 WANG Wenbing3 CHAI Lunlei1 WANG Xing1.Study on the Safety Risk Criterion for Personnel Escape in Highway Tunnel Fires under the Concept of Life Value and Injury Value[J]. MODERN TUNNELLING TECHNOLOGY, 2021,58(1): 84-91
[4] .[J]. MODERN TUNNELLING TECHNOLOGY, 2018,55(5): 159-165
[5] LI Tao- 1, 2 Zhang-Yu-Chun- 2 Ma- Jian- 1 Xiao- Han- 2.Experimental Study on Suppressing and Extinguishing of a Diesel Oil Pool Fire with the Water Mist System in a Large-Section Tunnel[J]. MODERN TUNNELLING TECHNOLOGY, 2017,54(1): 40-47
[6] YAN Zhi-Guo- 1, 2 Tian- Ye- 1, 2 Zhu-He-Hua- 1, 2 Shi-Yong-Quan- 3 Yu-Li-Yang- 4.Tunnel Fire Dynamic Early-Warning, Evacuation and Rescue System and Its Application[J]. MODERN TUNNELLING TECHNOLOGY, 2016,53(6): 31-35
[7] Guo Xiaoping1 Zhang Qihui2 Xu Shulin2 Simone Eandi2 Giuseppe Astore2 Piergiorgio Grasso2.Logarithmic ThA eory of Longitudinal Fire Ventilation in Tunnels[J]. MODERN TUNNELLING TECHNOLOGY, 2013,50(2): 39-45
[8] Tian Shixiong Tang Xuejun Wang Yonggang Zhang Tongwei.Investigation and Treatment of Extensive Fire Damage in the New Qidaoliang Tunnel[J]. MODERN TUNNELLING TECHNOLOGY, 2013,50(2): 181-186
Copyright 2010 by MODERN TUNNELLING TECHNOLOGY