Download: PDF (3865KB)   HTML (1KB)   Export: BibTeX or EndNote (RIS)      Supporting Info
摘要 间断级配砂土地层盾构隧道在运营期间面临管片接缝渗漏风险,渗漏水会携带细小土颗粒脱离粗颗粒骨架进入隧道内部,引发地层潜蚀,但其发展演化规律以及对地层稳定性和隧道结构的影响机制尚不明确。因此,采用自主研发的可视化盾构隧道地层潜蚀试验系统,结合水土压力动态监测与流失量定量采集,综合研究潜蚀全过程特征及其影响。试验选用细颗粒含量为35%的间断级配砂土,渗漏孔的直径设定为小于2倍粗颗粒粒径,并以20 kPa恒定渗流水压为边界条件诱发潜蚀。试验结果表明,潜蚀过程中砂土流失速率在初始阶段达到峰值后逐渐衰减并最终停止流失,而渗漏水速率则持续递增;地层潜蚀先由渗漏孔附近开始,逐步扩展形成“U”型潜蚀区,并伴随地层变形及地表沉降;潜蚀开始后,隧道环向各部位压力均出现下降,隧道顶部地层细颗粒显著流失,压力下降约70%,可能导致隧道结构上浮及横向收敛变形。
Service
把本文推荐给朋友
加入我的书架
加入引用管理器
Email Alert
RSS
作者相关文章
陈思睿1 张冬梅1
2 谢小创1 张学亮1
关键词盾构隧道   渗流侵蚀   潜蚀   模型试验     
Abstract: For shield tunnels constructed in gap-graded sandy soils are subject to a significant risk of segment joint leakage during operation. Seepage flow may transport fine soil particles away from the coarse-grained skeleton into the tunnel interior, resulting in suffusion. However, the developmental mechanism of suffusion and its influence on ground stability and tunnel structure remain unclear. In this study, a self-developed visualized test system for tunnel suffusion was employed, coupled with dynamic monitoring of water and soil pressures and quantitative measurement of soil loss, to investigate the characteristics and impacts of the entire suffusion process. A gap-graded sand with 35% fines content was selected. The leakage hole diameter was set to less than twice the coarse particle size, and a constant hydraulic head of 20 kPa was applied to induce suffusion. Test results show that the soil loss rate reaches a peak at the initial stage and gradually decreases until particle migration ceases, while the seepage discharge continuously increases. The suffusion initiates near the leakage hole and progressively expands to form a U-shaped erosion zone, accompanied by stratum deformation and surface settlement. After suffusion onset, circumferential loads around the tunnel decrease, with approximately 70% reduction observed above the tunnel due to severe fines loss, which may lead to tunnel uplift and lateral convergence deformations.
KeywordsShield tunnel,   Seepage erosion,   Suffusion,   Model test     
基金资助:国家自然科学基金(52238010,52408436);国家重点研发计划课题(2022YFC3800905);上海市白玉兰人才计划浦江项目(23PJD104).
作者简介: 陈思睿(2000-),男,博士研究生,主要从事盾构隧道周边土体渗流侵蚀方面研究,E-mail:dancychen@tongji.edu.cn.
引用本文:   
陈思睿1 张冬梅1, 2 谢小创1 张学亮1 .间断级配砂层盾构隧道潜蚀发展规律试验研究#br#[J]  现代隧道技术, 2025,V62(5): 225-
CHEN Sirui1 ZHANG Dongmei1, 2 XIE Xiaochuang1 ZHANG Xueliang1 .Experimental Study on the Development Law of Suffusion in Shield Tunnels within Gap-graded Sandy Strata[J]  MODERN TUNNELLING TECHNOLOGY, 2025,V62(5): 225-
链接本文:  
http://www.xdsdjs.com/CN/      或     http://www.xdsdjs.com/CN/Y2025/V62/I5/225
 
没有本文参考文献
[1] 马 畅1,2 郭英杰1,2,3 丁文其1,2 张清照1,2.波纹板加固盾构隧道管片纵缝力学性能研究[J]. 现代隧道技术, 2025,62(5): 154-
[2] 刘四进1 马浴阳1 周小涵2 喻星乔1 徐 梁2 王 ?2.海底盾构隧道施工期温度场演化与通风风量动态调控研究[J]. 现代隧道技术, 2025,62(5): 161-
[3] 李垂忝1 邹 波2 卢清碧3 彭 洋3 况 彦3 熊光义3 肖凤龙4.富水砂质地层基坑注浆止水堵漏扩散效果研究[J]. 现代隧道技术, 2025,62(5): 198-
[4] 龙海平1 卢清碧2 况 彦2 朱志良2 熊光义2 吴士流2 胡子威3 .强透水砂土地层盾构隧道开挖面极限支护力计算方法[J]. 现代隧道技术, 2025,62(5): 36-
[5] 张永杰1 张新宇1 陈剑华1,2 欧雪峰1 罗志敏1 吴杭辉1.顶管管节在复杂偏转模式下的应力响应与变形机制研究[J]. 现代隧道技术, 2025,62(5): 172-
[6] 周 龙1 卢 浩2 夏梦涛3 张文超4 石国庆4 陈丹鹤5.内爆炸荷载作用下盾构隧道抗爆性能试验研究[J]. 现代隧道技术, 2025,62(5): 231-
[7] 黄力平1 雷江松1 宋天田1 张 凯2 吕军鹏2 娄在明2 李凯迪1 张建鸣3 韩 然3 .高能宇宙线缪子成像技术在盾构隧道中的应用[J]. 现代隧道技术, 2025,62(5): 251-
[8] 郭永军1 李 超2 郑建国3 于永堂4 朱才辉5.地面堆载对西安黄土地层中既有盾构管片影响研究[J]. 现代隧道技术, 2025,62(4): 61-72
[9] 周弋力1 封 坤1 郭文琦1 张亮亮2 李春林3.超大直径盾构隧道管片纵缝抗弯力学行为与损伤过程研究[J]. 现代隧道技术, 2025,62(4): 163-173
[10] 易 丹1 薛皓匀2 杨绍毅2 喻 波1 封 坤2 林 刚1.盾构隧道管片结构螺栓失效对横向地震响应的影响分析[J]. 现代隧道技术, 2025,62(4): 174-181
[11] 贾永刚1 郝子晗1 鲁卫东1 吴 帆1 阳卫卫2.钢纤维混凝土管片不同接头型式力学性能研究[J]. 现代隧道技术, 2025,62(4): 182-196
[12] 谭鑫雨1 韦 猛1,2 兰灵申1 尚 强1 张海涛1.盾构刀盘结泥饼土体降黏附试验与机理研究[J]. 现代隧道技术, 2025,62(4): 219-229
[13] 刘朋飞1,2 曾德星2 王 霄3 杨 钊2 李 钰2.盾构泥饼分解剂作用效果评价试验及应用研究[J]. 现代隧道技术, 2025,62(4): 230-237
[14] 张小龙.桩基荷载作用下地铁盾构隧道结构力学响应分析[J]. 现代隧道技术, 2025,62(4): 82-89
[15] 胡云进1,,2,3 朱铭伟1,2,3 郜会彩1,2,3 任智豪1,2,3.地下水渗流对能源盾构隧道换热性能的影响[J]. 现代隧道技术, 2025,62(3): 50-59
Copyright 2010 by 现代隧道技术