Study on the Ambient Temperature Control Technology for Construction of a Tunnel Near Heat-conducting Fault and with High Rock Temperature
(1. School of Civil Engineering, North China University of Technology, Beijing 100144; 2. School of Civil Engineering, Beijing Jiaotong University, Beijing 100044; 3. Road and Bridge Engineering Department of Hebei Jiaotong Vocational & Technical College,Shijiazhuang 050035; 4. China Railway 16th Bureau Group 4th Engineering Co., Ltd., Beijing 101400)
Download: PDF (4652KB)   HTML (1KB)   Export: BibTeX or EndNote (RIS)      Supporting Info
Abstract In order to investigate the ambient temperature control technology for construction of a tunnel near heatconducting fault and with high rock temperature, the cooling effectiveness of the solutions including mechanical ventilation + ice, mechanical ventilation + mist spray and mechanical ventilation + ice + mist spray has been studied under different mechanical ventilation rates by using a tunnel project with high rock temperature as the study case.The results indicate: greater mechanical ventilation rate enables faster cooling rate and greater temperature drop;when mechanical ventilation rate is increased to a certain level, the tunnel cooling effectiveness is no longer improved notably, and other auxiliary measures are needed to further reduce temperature; in cooling by ice, consumption of more ice will bring faster cooling rate and better cooling effectiveness; in the mechanical ventilation + ice +mist spray solution, the average cooling rate is 5.37 °C/min, temperature drop is 53.74 °C and the stable ambient temperature is 26.26 °C, so this solution is the most effective solution for ambient temperature control in tunnel construction; when this temperature control solution is applied on site, the rock temperature at tunnel face is reduced to 46.1°C and the ambient temperature in tunnel is 25~27 °C, which meets the applicable standard.
Service
Email this article
Add to my bookshelf
Add to citation manager
Email Alert
RSS
Articles by authors
CUI Guangyao1 WEI Yifei1 XIONG Yong1 WANG Daoyuan2
3 TIAN Xiaolu4
KeywordsTunnels with high rock temperature   Heat-conducting fault   Ambient temperature during construction; Mechanical ventilation   Cooling by ice   Cooling by mist spray     
Abstract: In order to investigate the ambient temperature control technology for construction of a tunnel near heatconducting fault and with high rock temperature, the cooling effectiveness of the solutions including mechanical ventilation + ice, mechanical ventilation + mist spray and mechanical ventilation + ice + mist spray has been studied under different mechanical ventilation rates by using a tunnel project with high rock temperature as the study case.The results indicate: greater mechanical ventilation rate enables faster cooling rate and greater temperature drop;when mechanical ventilation rate is increased to a certain level, the tunnel cooling effectiveness is no longer improved notably, and other auxiliary measures are needed to further reduce temperature; in cooling by ice, consumption of more ice will bring faster cooling rate and better cooling effectiveness; in the mechanical ventilation + ice +mist spray solution, the average cooling rate is 5.37 °C/min, temperature drop is 53.74 °C and the stable ambient temperature is 26.26 °C, so this solution is the most effective solution for ambient temperature control in tunnel construction; when this temperature control solution is applied on site, the rock temperature at tunnel face is reduced to 46.1°C and the ambient temperature in tunnel is 25~27 °C, which meets the applicable standard.
KeywordsTunnels with high rock temperature,   Heat-conducting fault,   Ambient temperature during construction; Mechanical ventilation,   Cooling by ice,   Cooling by mist spray     