Home | About Journal  | Editorial Board  | Instruction | Subscription | Advertisement | Message Board  | Contact Us | 中文
MODERN TUNNELLING TECHNOLOGY 2014, Vol. 51 Issue (5) :150-154    DOI:
Article Current Issue | Next Issue | Archive | Adv Search << [an error occurred while processing this directive] | [an error occurred while processing this directive] >>
Simulation and Analysis of the Glare Effects of Highway Tunnel Lighting
(Hangzhou City Construction and Development Co. Ltd., Hangzhou 310000, Zhejiang)
Download: PDF (0KB)   HTML (1KB)   Export: BibTeX or EndNote (RIS)      Supporting Info
Abstract In order to reduce the impact of glare on the safety of highway tunnels, the area in a highway tunnel affected by lighting glare was studied by combining analog simulation and quantitative analysis. Using a calculation method introducing the glare constant G and relative threshold increment T1, the glare-affected areas generated by three kinds of glare arrangements, i.e., symmetrical, staggered, and centralized, were obtained by a simulative analysis of tunnel lighting glare. The results show that the glare-affected area for the symmetrical arrangement is 75.73°, 76.22° for the centralized one, and 79.58° for the staggered one. Based on the calculation analysis of glare constant G, the following conclusion was drawn: no matter which kind of luminaire arrangement is applied in tunnel lighting, once glare impact occurs, the drivers in the tunnel will be endangered.
Service
Email this article
Add to my bookshelf
Add to citation manager
Email Alert
RSS
Articles by authors
FU Yi
YANG Bo
CHEN Yun-Qing
Keywords Tunnel lighting   Glare analysis   Threshold increment   Glare parameters   Recovery time     
Abstract: In order to reduce the impact of glare on the safety of highway tunnels, the area in a highway tunnel affected by lighting glare was studied by combining analog simulation and quantitative analysis. Using a calculation method introducing the glare constant G and relative threshold increment T1, the glare-affected areas generated by three kinds of glare arrangements, i.e., symmetrical, staggered, and centralized, were obtained by a simulative analysis of tunnel lighting glare. The results show that the glare-affected area for the symmetrical arrangement is 75.73°, 76.22° for the centralized one, and 79.58° for the staggered one. Based on the calculation analysis of glare constant G, the following conclusion was drawn: no matter which kind of luminaire arrangement is applied in tunnel lighting, once glare impact occurs, the drivers in the tunnel will be endangered.
Keywords Tunnel lighting,   Glare analysis,   Threshold increment,   Glare parameters,   Recovery time     
published: 2014-08-27
Cite this article:   
FU Yi, YANG Bo, CHEN Yun-Qing .Simulation and Analysis of the Glare Effects of Highway Tunnel Lighting[J]  MODERN TUNNELLING TECHNOLOGY, 2014,V51(5): 150-154
URL:  