秦岭马白山隧道新型紧急救援站结构型式研究

Study on New Structural Type of the Emergency Rescue Station of Mabaishan Tunnel in Qinling Mountains

  • 摘要: 针对艰险山区高速铁路隧道的防灾救援难题,文章依托秦岭马白山隧道,提出了适合该隧道的新型紧急救援站结构型式,并利用FDS软件模拟隧道内纵向通风时列车着火后的烟气扩散,确定了规范中尚未给出的紧急救援站隔离区长度参数。结果表明:(1)秦岭马白山隧道新型紧急救援站结构型式应包括疏散区、隔离区以及待避救援区;(2)利用FDS数值模拟时,在不考虑纵向通风下,烟气沿下坡方向的扩散长度为295 m;考虑沿下坡方向通风时烟气最远扩散长度为980 m,建议隔离区长度设置为1 000 m。

     

    Abstract: Regarding the disaster prevention and rescue problems of high-speed railway tunnels in dangerous moun? tainous areas, a new type of emergency rescue station structure suitable for such tunnels is put forward based on actual conditions of Mabaishan Tunnel in Qinling Mountains. Using FDS software it simulates the smoke diffusion under longitudinal ventilation in a scenario of train fire in the tunnel, and determines the length parameter of the isolation area for emergency rescue station, which is not given in specifications. The results show that: (1) the new structural type of the emergency rescue station of Mabaishan Tunnel in Qinling Mountains should include evacuation area, isolation area and refuge area for rescue. (2) By FDS numerical simulation, the diffusion length of smoke along the downhill direction is 295 m without considering longitudinal ventilation, and the longest diffusion length of smoke along the downhill direction is 980 m with considering longitudinal ventilation. It is recommended to set the length of isolation area as 1 000 m.

     

/