[an error occurred while processing this directive]
 
       首 页  |  期刊介绍  |  编委会  |  投稿指南  |  期刊订阅  |  广告合作  |  留言板  |  联系我们 |  English
现代隧道技术 2025, Vol. 62 Issue (2) :221-229    DOI:
试验与监测 最新目录 | 下期目录 | 过刊浏览 | 高级检索 << [an error occurred while processing this directive] | [an error occurred while processing this directive] >>
向上顶管技术竖井管片密封垫设计及试验研究
(1.中铁工程装备集团有限公司,郑州 450016;2.城市地下空间开发技术与装备研发分中心,郑州 450016; 3.郑州大学机械与动力工程学院,郑州 450001)
Design and Experimental Research on Segment Sealing Gasket of Vertical Shaft Using Upward Pipe Jacking Technology
(1. China Railway Engineering Equipment Group Co., Ltd., Zhengzhou 450016; 2. Urban Underground Space Development Technology and Equipment Research and Development Sub-center, Zhengzhou, 450016; 3. School of Mechanical and Power Engineering,Zhengzhou University, Zhengzhou 450001)
Download: PDF (6178KB)   HTML (1KB)   Export: BibTeX or EndNote (RIS)      Supporting Info
摘要  为研究向上顶管竖井施工中预制竖井管片的防水和拼装性能,通过ABAQUS/Explicit对3种截面形式的密封垫进行有限元模拟,分析比较后针对性研制出一款耐水压高、压缩性强的管片密封垫,并依次开展压缩装配试验、水密试验及径向拼装试验,分析密封垫在不同接缝张开量、错台量条件下的物理力学性能。研究结果表明:接缝张开量和错台量与密封垫防水性能呈负相关关系,为达到防水压力设计值0.8 MPa,管片接缝张开量须保持在6 mm以内,错台量控制在10 mm以内;径向拼装时密封垫纵向变形近似呈弓形,即中间变形最大,两侧逐渐缩小,拼装时应注意挤压变形引起的错台问题;径向拼装推进力与接缝张开量呈负相关关系,为满足防水性能和拼装变形控制要求,可考虑采用扩径拼装方式,管片块间预设的张开量应大于9 mm。
Service
把本文推荐给朋友
加入我的书架
加入引用管理器
Email Alert
RSS
作者相关文章
白中坤1
2 王亚威1
2 毕程程1
2 赵修旺1
2 朱 强3
关键词向上顶管   竖井管片   密封垫   防水性能   拼装性能     
Abstract: In order to study the waterproof and assembly performance of prefabricated vertical shaft segments in up? ward pipe jacking construction, finite element simulations of sealing gaskets with three different cross-sectional forms were performed using ABAQUS/ Explicit. After comparison and analysis, a sealing gasket with high water pressure resistance and strong compressibility was specifically developed. Compression assembly tests, water-tightness tests, and radial assembly tests were conducted sequentially to analyze the physical and mechanical properties of the sealing gasket under different joint opening and misalignment conditions. The results show that the joint opening and misalignment are negatively correlated with the waterproof performance of the sealing gasket. To achieve the designed waterproof pressure value of 0.8 MPa, the joint opening should be kept within 6 mm, and the misalignment should be controlled within 10 mm. During radial assembly, the longitudinal deformation of the sealing gasket is approximately in arc-shape, with the maximum deformation at the center and gradually decreasing at the sides. Attention should be paid to misalignment caused by squeezing deformation during assembly. The radial assembly thrust is negatively correlated with joint opening. To meet the waterproof performance and assembly deformation control requirements, an expanding diameter assembly method can be considered, with the pre-set joint opening between the segments greater than 9 mm.
KeywordsUpward pipe jacking,   Vertical shaft segments,   Sealing gasket,   Waterproof performance,   Assembly per? formance     
基金资助:中铁工程装备集团有限公司科研项目(装备研合-2021-29);郑洛新国家自主创新示范区首批创新引领型产业集群专项 (181200210100).
作者简介: 白中坤(1985-),男,高级工程师,主要从事隧道及地下工程新技术方面的工作,E-mail:263090693@qq.com. 通讯作者:王亚威(1996-),男,硕士,主要从事隧道及地下工程设计与科研方面的工作,E-mail:1354410136@qq.com.
引用本文:   
白中坤1, 2 王亚威1, 2 毕程程1等 .向上顶管技术竖井管片密封垫设计及试验研究[J]  现代隧道技术, 2025,V62(2): 221-229
BAI Zhongkun1, 2 WANG Yawei1, 2 BI Chengcheng1 etc .Design and Experimental Research on Segment Sealing Gasket of Vertical Shaft Using Upward Pipe Jacking Technology[J]  MODERN TUNNELLING TECHNOLOGY, 2025,V62(2): 221-229
链接本文:  
http://www.xdsdjs.com/CN/      或     http://www.xdsdjs.com/CN/Y2025/V62/I2/221
 
没有本文参考文献
[1] 肖明清1 钟元元2 陈 鹏3 王 峻4 戚兆臣5 张卫斌6.盾构隧道管片接缝密封垫气密性提升试验研究[J]. 现代隧道技术, 2023,60(6): 262-268
[2] 肖明清 1,2 唐宇恒 3 陈俊伟 1,2 张超勇 3,4.盾构隧道管片接缝气体泄漏模型及影响因素分析[J]. 现代隧道技术, 2023,60(4): 6-13
[3] 薛光桥 1 虞雄兵 3 肖明清 1,2 张超勇 3,4 何应道 1,.考虑压缩-错缝-外部水压的密封垫防水性能数值模拟研究[J]. 现代隧道技术, 2023,60(3): 139-145
[4] 杨振华.浅覆土接收盾构隧道环间压力分布规律研究[J]. 现代隧道技术, 2022,59(5): 18-26
[5] 贺创波 1,2,3 许 超 1,2,3 杨 钊 1,2,3 刘朋飞 1,2,3 郑甲佳 4 高如超 1,2,3.考虑沟槽边界和粘贴质量的管片密封垫防水性能研究[J]. 现代隧道技术, 2022,59(5): 195-201
[6] 文彦鑫 1 霍永鹏 2 吴 悦 2 常 鑫 1 张 天 2 晏启祥 2.高水压盾构隧道管片密封垫装配力与防水性能研究[J]. 现代隧道技术, 2022,59(4): 273-
[7] 李 燚 1,2 丁文其 1,2 杨林松 3 谢东武 1,2.盾构隧道管片接缝渗漏水嵌缝处理试验研究[J]. 现代隧道技术, 2021,58(5): 167-172
[8] 赵国云 1 吴卫华 2 李书亮 3.沉管隧道混凝土路面沥青保护层关键性能研究[J]. 现代隧道技术, 2020,57(6): 142-148
[9] 陈云尧 1,2 张军伟 1 马士伟 2 李 雪 1.盾构隧道管片接缝密封垫设计参数研究[J]. 现代隧道技术, 2020,57(4): 59-66
[10] 温竹茵.周家嘴路越江隧道管片接缝防水技术研究[J]. 现代隧道技术, 2019,56(2): 152-157
[11] 吴炜枫 1, 2 丁文其 1, 2 魏立新 3 杨光华 4.深层排水盾构隧道接缝防水密封垫形式试验研究[J]. 现代隧道技术, 2016,53(6): 190-195
[12] 赵 明1, 2 丁文其1, 2 彭益成1, 2 沈碧伟1, 2 郭小红3 杨林松3.高水压盾构隧道管片接缝防水可靠性试验研究[J]. 现代隧道技术, 2013,50(3): 87-93
Copyright 2010 by 现代隧道技术