寒区隧道纵向温度场分布特征的模型试验研究
(1 国家山区公路工程技术研究中心,重庆 400067;2 中铁西南科学研究院有限公司,成都 611731;3 四川省隧道安全工程技术研究中心,成都 611731;4 招商局重庆交通科研设计院有限公司,重庆 400067)
Model Test Study on Distribution Characteristics of Longitudinal Temperature Field in Tunnels in Cold Regions
(1 National Engineering and Research Center for Mountainous Highways, Chongqing 400067; 2 China Railway Southwest Research Institute Co., Ltd., Chengdu 611731; 3 Sichuan Provincial Engineering Technology Research Center of Tunnel Safety, Chengdu 611731; 4 China Merchants Chongqing Communications Technology Research & Design Institute Co., Ltd., Chongqing 400067)
Download: PDF (6830KB)   HTML (1KB)   Export: BibTeX or EndNote (RIS)      Supporting Info
摘要 为分析寒区隧道洞内纵向温度场的分布规律及影响因素,研制了一种模拟寒区隧道纵向温度场分布的室内模型试验装置,分析了隧道长度、洞口气温和风速对寒区隧道纵向温度场分布的影响及其规律。结果表明:当洞口风速越小、洞口温度越高时,隧道长度对洞内纵向负温长度的影响越小;当洞口风速超过某一临界值、洞口温度低于某一临界值时,伴随隧道长度的增加,洞内纵向负温长度呈线性增大。当洞口风速越大、隧道长度越短,洞口温度对洞内纵向负温长度的影响越小;洞口风速一定的条件下,当隧道长度足够长时,伴随洞口温度降低,隧道内纵向负温长度呈线性增大。纵向防冻设防长度与洞口风速之间服从幂函数关系。洞口气温与风速对寒区隧道温度场的影响有相互促进、相互加强的作用。各因素对寒区隧道纵向温度场的影响程度排序为:洞口风速>洞口气温>隧道长度;针对具体寒区隧道,防冻设计应综合考虑各方面的因素并进行具体分析。
Service
把本文推荐给朋友
加入我的书架
加入引用管理器
Email Alert
RSS
作者相关文章
郭 瑞 1
2
3 郑 波 2
3 方 林 1
4 吴 剑 2
3
关键词:   
Abstract: As for the distribution law and influencing factors of longitudinal temperature field in tunnels in cold re? gions, an indoor model test device is developed to analyze the effects of tunnel length, temperature and air velocity at the tunnel portal on distribution of longitudinal temperature field in tunnels in cold regions. The results show that the influence of tunnel length on longitudinal length under negative temperature is smaller when the air velocity at the tunnel portal is smaller and the temperature at the portal is higher; the longitudinal length under negative temperature in the tunnel increases linearly as a function of tunnel length when the air velocity at the tunnel portal exceeds a certain critical value and the temperature at the portal is lower than a certain critical value; the influence of the temperature at the portal on the longitudinal length under negative temperature in the tunnel is smaller when the air velocity the tunnel portal is higher and the tunnel length is shorter; under a certain air velocity at the tunnel portal, the longitudinal length under negative temperature in the tunnel increases linearly along with the decrease of the temperature at the portal when the tunnel length is long enough. The relationship between the longitudinal antifreezing fortification length and the air velocity at the portal follows a power function. The influences of temperature and air velocity at the portal on temperature field in tunnels in cold regions are promoted and strengthened with each other. The order of sensitivity of each factor to the longitudinal temperature field in tunnels in cold regions is: air velocity at the portal > air temperature at the portal > tunnel length. For a specific tunnel in cold regions, various factors should be comprehensively considered, and specific analysis should be made in terms of the anti-freezing design.
KeywordsTunnel in cold region,   Temperature field,   Model test,   Air velocity,   Longitudinal anti-freezing fortifica? tion length     
基金资助:国家山区公路工程技术研究中心开放基金(GSGZJ-2017-01);四川省重点研发计划项目(2018GZ0359,2020YFS0500);中国中铁股份有限公司科技开发计划项目(CZ01-重大-01)
作者简介: 郭 瑞(1990-),男,硕士,工程师,主要从事隧道及地下工程领域的科研与咨询工作,E-mail:ruiguo07@163.com.
引用本文:   
郭 瑞 1, 2, 3 郑 波 2等 .寒区隧道纵向温度场分布特征的模型试验研究[J]  现代隧道技术, 2021,V58(5): 129-139
GUO Rui1, 2, 3 ZHENG Bo2 etc .Model Test Study on Distribution Characteristics of Longitudinal Temperature Field in Tunnels in Cold Regions[J]  MODERN TUNNELLING TECHNOLOGY, 2021,V58(5): 129-139
链接本文:  
http://www.xdsdjs.com/CN/      或     http://www.xdsdjs.com/CN/Y2021/V58/I5/129
 
没有本文参考文献
[1] 李瑞俊1 宋宗莹2 李 琛1 王文斌2 任育珍3,4 蔡建华3,4 张家旭3,4.重载铁路梁家山隧道病害多源融合诊断与处置对策[J]. 现代隧道技术, 2025,62(4): 301-308
[2] 张小龙.桩基荷载作用下地铁盾构隧道结构力学响应分析[J]. 现代隧道技术, 2025,62(4): 82-89
[3] 李克玺1,2 党建东3 张 见3 叶光祥4 王晓军1,2 陈青林1,2 曹世荣2 张 河1,2.基于声发射特征参数的不同类型砂岩破裂特征研究[J]. 现代隧道技术, 2025,62(4): 26-36
[4] 周彩荣1 易黎明1 马山青2 周 蠡3 于金弘4,5.三点加载下高性能纤维混凝土顶管承载特性及配筋方案研究[J]. 现代隧道技术, 2025,62(4): 50-60
[5] 郭永军1 李 超2 郑建国3 于永堂4 朱才辉5.地面堆载对西安黄土地层中既有盾构管片影响研究[J]. 现代隧道技术, 2025,62(4): 61-72
[6] 王永刚1 崔翌堃1 吴九七2,3 黄 俊4 沈 翔2,3 杨 奎4 苏 栋2,3.考虑不同磨损形式下的滚刀受力与磨损对比分析[J]. 现代隧道技术, 2025,62(4): 73-81
[7] 冯冀蒙1,2 宋佳黛1,2 王圣涛3 李艺飞1,2 张俊儒1,2 王好明4 汪 波1,2.填海地层特大断面隧道超长管棚变形控制 效能研究[J]. 现代隧道技术, 2025,62(4): 155-162
[8] 徐才坚1 陈星宇1 雷明林1 张兴龙2 孙怀远2 李晓军2.隧道施工掌子面前方围岩富水性数字孪生与风险决策[J]. 现代隧道技术, 2025,62(4): 90-99
[9] 杨 颖1 倪 凯1 葛 林2 张明飞3 王晓睿4.弱光条件下基于改进Unet模型的隧道渗水病害图像分割[J]. 现代隧道技术, 2025,62(4): 100-110
[10] 苏开春1 付 锐2,3 曾弘锐2,3 冷希乔4 郭 春2,3.基于DBO-A-LSTM的公路隧道短时多步交通量预测[J]. 现代隧道技术, 2025,62(4): 111-121
[11] 熊 颖1,2 张俊儒1,2 范子焱1,2 陈佳豪1,2 马荐驰1,2 陈鹏涛1,2 谭瑞锋3,4.层状软岩中爆破应力波传播与振动衰减特性研究[J]. 现代隧道技术, 2025,62(4): 122-131
[12] 刘 杨1 邵泽楷2 田浩帆2 张汝溪1 郑 波3 王峥峥2.高速公路隧道下穿房柱式煤矿采空区爆破施工煤柱 损伤规律研究[J]. 现代隧道技术, 2025,62(4): 132-144
[13] 罗志洋1 张春瑜2,3 王立川1,2,4,5 徐 烁1 李利平4 王倩倩5 刘志强6.TBM裂隙岩体隧洞涌水机制及注浆堵水研究[J]. 现代隧道技术, 2025,62(4): 145-154
[14] 周弋力1 封 坤1 郭文琦1 张亮亮2 李春林3.超大直径盾构隧道管片纵缝抗弯力学行为与损伤过程研究[J]. 现代隧道技术, 2025,62(4): 163-173
[15] 易 丹1 薛皓匀2 杨绍毅2 喻 波1 封 坤2 林 刚1.盾构隧道管片结构螺栓失效对横向地震响应的影响分析[J]. 现代隧道技术, 2025,62(4): 174-181
Copyright 2010 by 现代隧道技术