Home | About Journal  | Editorial Board  | Instruction | Subscription | Advertisement | Message Board  | Contact Us | 中文
MODERN TUNNELLING TECHNOLOGY 2022, Vol. 59 Issue (6) :51-60    DOI:
Current Issue | Next Issue | Archive | Adv Search << [an error occurred while processing this directive] | [an error occurred while processing this directive] >>
Study on Rapid Assessment of Battle-induced Structure Damage Based on the Subway Station Target
(1. Jinan Rail Transit Group Co., Ltd., Jinan 250014; 2. Shandong Rail Transit Survey and Design Institute Co., Ltd., Jinan 250014)
Download: PDF (2896KB)   HTML (1KB)   Export: BibTeX or EndNote (RIS)      Supporting Info
Abstract Analytical research was conducted systematically on the battle-induced structure damage based on the subway station target, and combined with the common ways to strike the urban subway station structure with conventional weapons, a simple analysis of target characteristics was carried out and a calculation and assessment flow was established for the battle damage to the subway station structure. Based on the establishment of the criteria for damage, a more detailed analysis of battle-induced structure damage was conducted, key parameters, such as radius of collapse, peak value of equivalent uniformly distributed dynamic load at different areas, vibration acceleration and vibration time, were calculated, and calculation was illustrated according to the specific examples of penetration and explosion above the subway station. From the results of calculation, it can be seen that the established method and flow of calculation and assessment of battle-induced structure damage can rapidly and accurately evaluate the damage to subway stations and also provide a useful reference for research into the protection of subway stations and emergency repair and rescue after battle-induced structure damage.
Service
Email this article
Add to my bookshelf
Add to citation manager
Email Alert
RSS
Articles by authors
LI Hu1
2 HAN Gang1 HUANG Yongliang1 SONG Xie1 LI Dayong1
KeywordsSubway station   Target characteristic analysis   Battle-induced structure damage calculation   Rapid damage assessment     
Abstract: Analytical research was conducted systematically on the battle-induced structure damage based on the subway station target, and combined with the common ways to strike the urban subway station structure with conventional weapons, a simple analysis of target characteristics was carried out and a calculation and assessment flow was established for the battle damage to the subway station structure. Based on the establishment of the criteria for damage, a more detailed analysis of battle-induced structure damage was conducted, key parameters, such as radius of collapse, peak value of equivalent uniformly distributed dynamic load at different areas, vibration acceleration and vibration time, were calculated, and calculation was illustrated according to the specific examples of penetration and explosion above the subway station. From the results of calculation, it can be seen that the established method and flow of calculation and assessment of battle-induced structure damage can rapidly and accurately evaluate the damage to subway stations and also provide a useful reference for research into the protection of subway stations and emergency repair and rescue after battle-induced structure damage.
KeywordsSubway station,   Target characteristic analysis,   Battle-induced structure damage calculation,   Rapid damage assessment     
Cite this article:   
LI Hu1, 2 HAN Gang1 HUANG Yongliang1 SONG Xie1 LI Dayong1 .Study on Rapid Assessment of Battle-induced Structure Damage Based on the Subway Station Target[J]  MODERN TUNNELLING TECHNOLOGY, 2022,V59(6): 51-60
URL:  
http://www.xdsdjs.com/EN/      或     http://www.xdsdjs.com/EN/Y2022/V59/I6/51
 
No references of article
[1] WEI Zhiyuan1 FENG Jimeng2 YU Longping2.Study on the Mechanical Behavior of the the Double-layer Arch Cover Initial Support during the Construction of Subway Stations by Arch-cover Method[J]. MODERN TUNNELLING TECHNOLOGY, 2022,59(3): 265-274
[2] HUANG Peng1,2 WEI Liangwen1,2 ZHANG Xuefu1,2.Study on Reinforcement of Large Arch Foot of Mined and Overlapped Metro Transfer Stations[J]. MODERN TUNNELLING TECHNOLOGY, 2021,58(6): 137-147
[3] ZHOU Wendi1,2 LIANG Qingguo1,2 ZHANG Jindong3.Analysis of the Deformation and Structural Stress of a Metro Station Constructed by Pile-Beam-Arch Method[J]. MODERN TUNNELLING TECHNOLOGY, 2021,58(6): 121-128
[4] ZHANG Zilong1 JIANG Annan1 YU Hai2 WANG Feng2.Analysis of the Mechanical Response in the Construction of Large-Span Mined Metro Stations by the Arch-Cover Method[J]. MODERN TUNNELLING TECHNOLOGY, 2021,58(3): 139-146
[5] CHEN Liang.Study on Selection of the Intermediate Pile Foundation of Subway Stations with Cut and Cover Top-down Method[J]. MODERN TUNNELLING TECHNOLOGY, 2021,58(2): 166-173
[6] JIANG Pin LI Yuanfu.Study on Risk Assessment in Subway Station Construction Based on Principal Component Analysis[J]. MODERN TUNNELLING TECHNOLOGY, 2021,58(1): 67-74
[7] ZHAN Xianjun PEI Taotao ZHOU Jibing.Visualization Analysis of Metro Station Deformation Based on Thermodynamic Diagram[J]. MODERN TUNNELLING TECHNOLOGY, 2020,57(1): 65-69
[8] YAN Tao1 LI Kunjie1 QIN Pengcheng1 CHEN Jingyu1,2 LIN Rui3 ZUO Qiang3.Calculation Method for the Surrounding Rock Pressure of Mined Lower Tunnel Structure of a Metro Station Built by Combination of Open Cut and Mined Method[J]. MODERN TUNNELLING TECHNOLOGY, 2020,57(1): 76-82
[9] CHEN Zhuo1,2 KONG Chao3.Study on the Influence of the Construction of Large-section Metro Station on Lateral Friction Resistance of Adjacent Pile Foundation[J]. MODERN TUNNELLING TECHNOLOGY, 2019,56(6): 114-120
[10] LI Fengyun.The Influential Factors on Instability of Slope during Excavation of a Metro Station Based on Upper Limit Analysis Method[J]. MODERN TUNNELLING TECHNOLOGY, 2019,56(5): 92-97
[11] LI Jidong1,2 YOU Xinhua1.Seismic Response of the Metro Station with Pre-constructed Pipe-roof Integrating Support and Structure under Strong Earthquake Effect[J]. MODERN TUNNELLING TECHNOLOGY, 2019,56(3): 72-78
[12] SHANG Youlei1 TAN Zhun2.Optimization of Mined Construction Method for the Super-large Section Liuhualu Station of Guangzhou Metro[J]. MODERN TUNNELLING TECHNOLOGY, 2019,56(3): 177-185
[13] ZHANG Weibiao.Drill-blast Excavation and Vibration Control of the Large-section Metro Station in Urban Areas[J]. MODERN TUNNELLING TECHNOLOGY, 2019,56(1): 185-191
[14] TANG Xiaorong1 ZHANG Liqun2 GUO Xi1 SHI Jinhui1 SUN Bole3.Research on Comprehensive Construction Technology for Retaining Structure of Special-shaped Deep Foundation Pit in Inclined Hard Rock[J]. MODERN TUNNELLING TECHNOLOGY, 2019,56(1): 205-208
[15] .[J]. MODERN TUNNELLING TECHNOLOGY, 2018,55(5): 115-123
Copyright 2010 by MODERN TUNNELLING TECHNOLOGY