Load-bearing Behavior and Reinforcement Schemes of High-performance Fiber-reinforced Concrete Jacking Pipes under Three-point Loading
(1. PowerChina Hubei Electric Engineering Co., Ltd., Wuhan 430040; 2. China Electric Power Research Institute Co., Ltd., Beijing 102401; 3. Economic and Technological Research Institute, State Grid Hubei Electric Power Co., Ltd., Wuhan 430077; 4. School of Hydraulic and Environmental Engineering, Changsha University of Science & Technology, Changsha 410114; 5. Key Laboratory of Water-Sediment Sciences and Water Disaster Prevention of Hunan Province, Changsha 410114)
Download: PDF (6233KB)   HTML (1KB)   Export: BibTeX or EndNote (RIS)      Supporting Info
Abstract High-performance fiber-reinforced concrete (HPFRC) exhibits significant potential for use in electricpower pipe-jacking engineering due to its superior strength, ductility, and durability. However, research on the mechanical properties of HPFRC jacking pipes remains scarce. This study investigates the load-bearing characteristics of C150 HPFRC jacking pipes under three-point loading and evaluates the influence of different reinforcement schemes through model tests, analytical calculations, and numerical simulations. The results indicate that the loaddisplacement relationship of HPFRC jacking pipes initially follows a linear elastic trend. When the load exceeds200 kN/m, the displacement accelerates, and cracks develop in the pipe segment. Structural failure occurs at a peak load of 437 kN/m. Compared to conventional concrete jacking pipes, HPFRC pipes demonstrate significantly improved load-bearing capacity, crack resistance, and post-damage residual strength while requiring less steel reinforcement and reduced wall thickness. The three analytical methods yield consistent results regarding structural stress behavior and failure progression. However, the analytical calculation method exhibits notable errors in predicting crack widths. Furthermore, different reinforcement schemes significantly influence structural damage and load capacity, with double-sided and inner-layer reinforcement configurations demonstrating superior damage resistance.
Service
Email this article
Add to my bookshelf
Add to citation manager
Email Alert
RSS
Articles by authors
ZHOU Cairong1 YI Liming1 MA Shanqing2 ZHOU Li3 YU Jinhong4
5
KeywordsHigh-performance fiber reinforced concrete   Pipe jacking   Three-point test   Load-bearing behavior; Reinforcement schemes     
Abstract: High-performance fiber-reinforced concrete (HPFRC) exhibits significant potential for use in electricpower pipe-jacking engineering due to its superior strength, ductility, and durability. However, research on the mechanical properties of HPFRC jacking pipes remains scarce. This study investigates the load-bearing characteristics of C150 HPFRC jacking pipes under three-point loading and evaluates the influence of different reinforcement schemes through model tests, analytical calculations, and numerical simulations. The results indicate that the loaddisplacement relationship of HPFRC jacking pipes initially follows a linear elastic trend. When the load exceeds200 kN/m, the displacement accelerates, and cracks develop in the pipe segment. Structural failure occurs at a peak load of 437 kN/m. Compared to conventional concrete jacking pipes, HPFRC pipes demonstrate significantly improved load-bearing capacity, crack resistance, and post-damage residual strength while requiring less steel reinforcement and reduced wall thickness. The three analytical methods yield consistent results regarding structural stress behavior and failure progression. However, the analytical calculation method exhibits notable errors in predicting crack widths. Furthermore, different reinforcement schemes significantly influence structural damage and load capacity, with double-sided and inner-layer reinforcement configurations demonstrating superior damage resistance.
KeywordsHigh-performance fiber reinforced concrete,   Pipe jacking,   Three-point test,   Load-bearing behavior; Reinforcement schemes     
Cite this article:   
ZHOU Cairong1 YI Liming1 MA Shanqing2 ZHOU Li3 YU Jinhong4, 5 .Load-bearing Behavior and Reinforcement Schemes of High-performance Fiber-reinforced Concrete Jacking Pipes under Three-point Loading[J]  MODERN TUNNELLING TECHNOLOGY, 2025,V62(4): 50-60
URL:  
http://www.xdsdjs.com/EN/      或     http://www.xdsdjs.com/EN/Y2025/V62/I4/50
 
No references of article
[1] CHENG Gaojun1 HE Lidong2 WANG Kui.Performance Analysis of Steel-concrete Composite Structures with Double-row Shear Studs under Large Eccentric Compression[J]. MODERN TUNNELLING TECHNOLOGY, 2025,62(3): 30-39
[2] LI Hanyuan1,2 FENG Jin1 GUO Hongyu1 XIE Xiongyao2 ZHOU Hongsheng1 SUN Fei.Study on the Combined Bearing Mechanical Characteristics of the Double-layer Lining Structure of Subsea Shield Tunnels[J]. MODERN TUNNELLING TECHNOLOGY, 2025,62(3): 126-138
[3] BAI Zhongkun1,2 WANG Yawei1,2 BI Chengcheng1,2 ZHAO Xiuwang1,2 ZHU Qiang3.Design and Experimental Research on Segment Sealing Gasket of Vertical Shaft Using Upward Pipe Jacking Technology[J]. MODERN TUNNELLING TECHNOLOGY, 2025,62(2): 221-229
[4] CHEN Wang1 PENG Yanfeng1 LIU Weizheng2 ZHANG Siyu2 CHEN Changhui1.Analysis of the Impact of the Three Pipe Jacking Over-crossing Construction on Existing Tunnel and Surface Deformation[J]. MODERN TUNNELLING TECHNOLOGY, 2025,62(1): 170-182
[5] JIN Zhengxing1 GUO Ping2 ZHOU Wenpeng1 HU Qiao? SU Dong3 ZHAO Jiaxin1 SUN Bo?.Research on Construction Posture Control Technology for Shallow Buried Extra-large Section Combined Rectangular Pipe Jacking with Tight Gaps[J]. MODERN TUNNELLING TECHNOLOGY, 2025,62(1): 259-266
[6] XUE Qingsong.Deformation Distribution Characteristics and Control Measures of Large-section Rectangular Pipe Jacking Over-crossing Metro Tunnels[J]. MODERN TUNNELLING TECHNOLOGY, 2024,61(6): 148-161
[7] CUI Guangyao1 DAI Aimeng1 MA Jianfei2 NING Maoquan3.Study on Calculation Method and Influencing Factors of Carbon Emission during Construction of Rectangular Pipe-jacking Tunnels[J]. MODERN TUNNELLING TECHNOLOGY, 2024,61(4): 126-134
[8] ZHU Yanfei1 GUO Yan1 WANG Jinyi1 MA Jianfeng2 PAN Weiqiang1.Research and Application of Full-Face Pipe Jacking Method in Saturated Soft Soil Layers for the Jing′an Temple Station Subway Project[J]. MODERN TUNNELLING TECHNOLOGY, 2024,61(2): 263-271
[9] XU Youjun1,2,3 KANG Jiawang1 ZHANG Chao1,2,3 HUANG Zhengdong1 ZHANG Xu1,2,3.Shear Failure Mechanism of F-type Socket-and-Spigot Joint in Rectangular Pipe Jacking Tunnels[J]. MODERN TUNNELLING TECHNOLOGY, 2023,60(3): 189-198
[10] SUN Yi.Analysis of Stress Characteristics and Stability of Initial Support Arch of Tunnels with the Spatial Effect of Truss Structure Taken into Consideration[J]. MODERN TUNNELLING TECHNOLOGY, 2023,60(3): 34-43
[11] SUN Huibin1 ZHANG Jianli2 YANG Huixiang1 YANG Hui2 WANG Lei3 WEI Jun2 LIN Weinan3.A Study on the Bearing Characteristics of Composite Concrete-filled Steel Tube Support Structure in Tunnels[J]. MODERN TUNNELLING TECHNOLOGY, 2023,60(2): 103-114
[12] CUI Guangyao1 MA Jianfei2 NING Maoquan3,4 TANG Zaixing3,4 LIU Shunshui3,4 TIAN Yuhang1.A Study on Optimization of Reinforcement Scheme for Adjacent Construction of Super-large Rectangular Pipe Jacking Shield Tunnel in Soft Ground[J]. MODERN TUNNELLING TECHNOLOGY, 2023,60(2): 178-184
[13] YAO Zhixiong1,2,3 LIU Mengfei1 WU Bo4 LIU Yaoxing1 CHEN Ximao5 ZHENG Guowen5 LUO Zhiyi1.Study on Stability and Initial Support Optimization of Multi-tunnel Based on Bearing Characteristics[J]. MODERN TUNNELLING TECHNOLOGY, 2023,60(1): 119-129
[14] XU Hong1 YE Fei2 LIU Qi1 TIAN Liming1 AN Huan1.Study on Stratum Deformation Caused by Large-section Rectangular Pipe Jacking and Jacking Parameter Control[J]. MODERN TUNNELLING TECHNOLOGY, 2022,59(6): 97-105
[15] ZHEN Liang1 ZHANG Xianyu2,3 LI Xiaojun2,3.On Discrimination Method and Treatment Measures for Overall Soil-carrying Effect of Shallow-buried Rectangular Pipe Jacking Projects[J]. MODERN TUNNELLING TECHNOLOGY, 2022,59(2): 167-171
Copyright 2010 by MODERN TUNNELLING TECHNOLOGY